Special procedures
Installer Manual -
TP8-96 VIDEO
A-12
TERMINALS
1
14V +
Battery charge voltage
Output
2
-
GND (earth)
-
3
SRA+
Self-powered sirens
Output
Stand-by:
13,8V DC
Alarm:
high impedance
4
SRA-
Negative voltage - Indoor self-powered sirens
-
Alarm:
negative voltage
5
+SR INT
Indoor siren
Output
6
-SR INT
GND (earth)
-
Stand-by :
high impedance (*)
Alarm:
negative voltage
7
OFF-
Logic stand-by output
Output
Control panel in stand-by:
negative voltage
Control panel armed:
high impedance
8
OUT4+
Programmable logic output
Output
Stand-by :
high impedance (*)
Alarm:
13,8V DC (*)
positive voltage
9
OUT2+
Programmable logic output
Output
Stand-by :
high impedance (*)
Alarm:
13,8V DC (*)
negative voltage
10
OUT1-
Programmable logic output
Output
Stand-by:
negative voltage
11
+
Power supply
Output
12
-
GND (earth)
Output
13
Z1
Zone 1
Input
14
COM
Common input
Input
15
Z2
Zone 2
Input
16
+
Positive voltage
Output
17
-
GND (earth)
Input
18
Z3
Zone 3
Input
19
COM
Common input
Output
20
Z4
Zone 4
Input
21
+
Positive voltage
Output
22
-
GND (earth)
Input
23
Z5
Zone 5
Input
24
COM
Common input
Output
25
Z6
Zone 6
Input
26
+
Positive voltage
Output
27
-
GND (earth)
-
28
Z7
Zone 7
Input
29
COM
Common input
Input
30
Z8
Zone 8
Input
31
ZT
Tamper input
Input
Stand-by
= closed
Alarm
= Open
32
PW R1+
Positive voltage - TVCC power supply
33
PW R1-
Negative voltage - TVCC power supply
34
PW R2+
Positive voltage - TVCC power supply
35
PW R2-
Negative voltage - TVCC power supply
36
PW R3+
Positive voltage - TVCC power supply
37
PW R3-
Negative voltage - TVCC power supply
38
PW R4+
Positive voltage - TVCC power supply
39
PW R4-
Negative voltage - TVCC power supply
40
AC
AC power supply voltage
Input
41
AC
AC power supply voltage
Input
1
+
Power supply RS485 serial bus
Output
2
-
Power supply RS485 serial bus
Output
3
A
RS485 serial bus
Input
4
B
RS485 serial bus
Output
5
S
Loudspeaker signal
Output
6
+
Power supply RS485 serial bus
Output
7
-
Power supply RS485 serial bus
Output
8
A
RS485 serial bus
Input
9
B
RS485 serial bus
Output
13,8V DC
NC / NO / BIL / B24 / ZBUS
13,8V DC
13,8V DC
13,8V DC
13,8V DC
14,4V DC - For self-powered siren
GND (earth)
NC / NO / BIL / B24 / ZBUS
13,8V DC
13,8V DC
NC / NO / BIL / B24 / ZBUS
13,8V DC
GND (earth)
13,8V DC
NC / NA / BIL / B24
13,8V DC
GND (earth)
NC / NA / BIL / B24
13,8V DC
GND (earth)
13,8V DC
NC / NA / BIL / B24
13,8V DC
GND (earth)
13,8V DC
GND (earth)
NC / NO / BIL / B24
NC / NA / BIL / B24
RS485 serial bus
RS485 serial bus
RS485 serial bus
14,4V DC
GND (earth)
Voice signal towards loudspeaker of the LCD300/S consoles
* De fault setting. NC (0 Ohm) - NO (superior to 2K Ohm) - BIL (2K Ohm … 4K Ohm) - B24 (2K Ohm … 4K Ohm)
Sta ndard inputs
Tamper input
Terminals
Pow er supply
RS485 serial bus
Siren bus
32V AC
32V AC
RS485 serial bus
Summary of Contents for TP8-96
Page 4: ...IV Installer Manual TP8 96 VIDEO...
Page 16: ...Introduction to the TP8 96 VIDEO system Installer manual TP8 96 VIDEO 1 10...
Page 17: ...TP8 96 VIDEO Installer manual Introduction to the TP8 96 VIDEO system 1 11...
Page 44: ...Zoneconfiguration Installer Manual TP8 96 VIDEO 2 26...
Page 60: ...Telephonesectionconfiguration Installer Manual TP8 96 VIDEO 3 16...
Page 66: ...Telephonesectionconfiguration Installer Manual TP8 96 VIDEO 3 22...
Page 76: ...Timeparameterconfiguration Installer Manual TP8 96 VIDEO 4 10 Test call server Access periods...
Page 88: ...Accessconfiguration Installer Manual TP8 96 VIDEO 5 12...
Page 102: ...Special procedures Installer Manual TP8 96 VIDEO A 2...
Page 111: ...TP8 96 VIDEO Installer Manual Special procedures A 11 ELECTRONIC BOARD...
Page 113: ...TP8 96 VIDEO Installer Manual Special procedures A 13 SYSTEM...
Page 114: ...Special procedures Installer Manual TP8 96 VIDEO A 14 CAMERA CONNECTION...
Page 115: ...TP8 96 VIDEO Installer Manual Special procedures A 15 SUPPLY BY TERMINALS...
Page 116: ...Special procedures Installer Manual TP8 96 VIDEO A 16 SUPPLY BY CABLES SPLITTER...
Page 117: ...TP8 96 VIDEO Installer Manual Special procedures A 17...