2. MAJOR UNIT REPLACEMENT
EO18-33011
2.3 REPLACING THE SOLENOID
2- 5
A
B
0.5 ~ 1.0 mm
Move the solenoid attachment plate while measuring a clearance between the print head and the
platen with a scale so as not to touch the print head with it. Secure the solenoid ass’y where the
clearance between the print head and the platen is 0.5 to 1.0 mm and distances A and B are equal.
Moving the solenoid ass’y in the direction of black arrow causes the print head position higher. Moving
the solenoid ass’y in the direction of white arrow causes the print head position lower.
Fig. 2-7
Platen
SMW-4x8 Screw
Solenoid Attachment
Plate
Print Head
Print Head
SMW-4x8 Screw
Scale
CAUTION!
Do not insert a scale or a clearance gauge between the print head and the platen. Doing so may
damage the print head element, causing a print failure such as missing dot.