![TEC B-490 SERIES Maintenance Manual Download Page 70](http://html1.mh-extra.com/html/tec/b-490-series/b-490-series_maintenance-manual_4022892070.webp)
6. SYSTEM MODE
EO18-33011
6.6 PRINTER PARAMETER FINE ADJUSTMENT
6-30
••••
Back Feed Length Fine Adjustment (Example)
NOTE:
The fine adjustment value equals to the sum of the fine adjustment values set by the
PC command and this parameter. The maximum back feed length fine adjustment
value is
±
9.5mm. When the value reached the maximum, the value remains
unchanged even if the subsequent fine adjustment is performed.
6.6.4 X Axis Fine Adjustment
With this parameter you can fine adjust the print position on X Axis. When “<3>ADJUST SET”
appears, press the [PAUSE] key 4 times.
[FEED] key:
Pressing the [FEED] key one time causes a –0.5mm change, up to –99.5 mm.
[RESTAT] key:
Pressing the [RESTART] key one time causes a +0.5mm change, up to +99.5
mm.
After completing the fine adjustment, press the [PAUSE] key.
X 0.0mm
[RESTART]
[FEED]
X 99.5mm
X 99.0mm
X 0.0mm
X ADJUST -99.0mm
X ADJUST -99.5mm