Operating the Equipment Locally: Remux
Reference Guide: Voyager E5784 and E5788 HD DSNG Encoder
Page 4-137
ST.RE.E10137.3
Selected Option
Description
New Services Default
This specifies whether new services detected on a Remux input will be ON (i.e. mapped
through) or OFF by default. (If PID Remap Status has reached the LOCKED stage, new
services will not be recognised at all.) A service is deemed to be new if, on power-up, the
acquired PSI shows that there is any differences to the make up of the services. In a
multi-level Remux system, if an upstream Encoder is power-cycled, the downstream Remux
Encoder may detect the service as NEW due to the way the PSI is built during power-up.
Therefore it is recommended that the New Services Default be set to ON unless there are
particular concerns about services causing an overflow.
Packet Length Option
This option indicates the packet length. See Section 4.10.4, Packet Length
Option for details.
Bit-rate Option
This option indicates the bit-rate. See Section 4.10.6, Bit-rate (188) and
Bit-rate (204) Option for details.
Status Only Options for the Remux Module Menu
The following options are status only and cannot be changed.
•
Spare Bit-rate
•
Input Bit-rate
•
Output Bit-rate
•
Host TS Output Rate
•
Host Data Rate
•
Input TS 1 (188)
•
Data Rate 1 (188)
•
Input TS 2 (188)
•
Data Rate 2 (188)
•
Input TS 3 (188)
•
Data Rate 3 (188)
•
Software Release
NOTE…
The maximum input bit-rate allowed on the Remux Module ASI inputs is 50 Mbit/s. If the input bit-rate
exceeds 86 Mbit/s it will be incorrectly reported as a lower rate.