Installing the Equipment
Page 2-6
Reference Guide: Voyager E5784 and E5788 HD DSNG Encoder
ST.RE.E10137.3
The unit is designed for stationary or fixed use only. Ensure it is firmly and
safely located and has an adequate through-flow of air. Allow at least
50 mm free air-space at each side of the equipment. Units in racks can be
stacked without ventilation panels between. Racks containing stacked
equipment may need to be forced-air cooled to reduce the operating
ambient temperature. For stacking constraints contact Customer Services.
It is important not to block the front air intake on the bottom-left corner of
the front panel (see Figure 2.2).
Figure 2.2: Air Path Through the Enclosure
NOTE…
Cooling arrangements in current models may differ to those shown.
Warm air out
Cool air in
(front – via bottom vent)
Cool air in