Technical Specification
Reference Guide: Voyager E5784 and E5788 HD DSNG Encoder
Page B-19
ST.RE.E10137.3
B.8 Environmental
Conditions
Table B.30: Environmental Specification
Item
Specification
Operational
Temperature -10
°
C to +50
°
C (14
°
F to 122
°
F) ambient with free air-flow
Over temperature alarm
generated at
>= 55°C
Under temperature alarm
generated at
< 0°C
Temperature checked
Once every 30 seconds
All fans switched off at
< 10°C (when set to auto)
Half the fans switched off at
< 20°C (when set to auto)
All fans on at
>= 20°C (when set to auto)
Relative humidity
0% to 90% (non-condensing)
Cooling requirements 2U
Front section: Cool air input from front panel, exhaust from right side of unit
Rear section: Cool air input from left side of unit, exhaust from right side of unit
See
Chapter 2, Installing the Equipment, Figure 2.2.
Handling/movement
Designed for stationary or fixed use when in operation
Storage/Transportation
Temperature
-20
°
C to +70
°
C (-4
°
F to 158
°
F)
Relative humidity
0% to 90% (non-condensing)
B.9 Compliance
1
B.9.1 Safety
This equipment has been designed and tested to meet the requirements of
the following:
EN 60950
European
Safety of information technology equipment.
IEC 60950
International
Safety of information technology equipment.
In addition, the equipment has been designed to meet the following:
UL 60950
USA
Safety of information technology equipment.
1