Tandberg StorageLibrary T128 User’s Guide
53
You cannot configure the security settings from the web client. The path to open the appropriate screen is
as follows:
•
From the operator panel, select
Tools > Security Settings
.
Configuring the Internal Network
Use the
Internal Network Configuration
screen to configure your library’s internal network setting. The
default internal network address is
10.10.10.
X
.
The library’s internal network enables communication among library components. While rare, it is possible
that the default addressing of the internal network could conflict with your network, potentially causing the
library to become confused. When installing the library, make sure that the external network setting is
different than the internal network setting on the library. If DHCP is enabled or you do not know what your
external network setting is, check with your network administrator.
From the operator panel, administrative users can change the setting of the internal network using the
Internal Network Configuration
screen. Select the new internal IP address from the list on the screen. You
can select from nine IP addresses.
The
Internal Network Configuration
screen is only accessible from the operator panel. The path to open
the appropriate screen is as follows:
•
From the operator panel, select
Tools > Internal Network
.
Configuring System Settings
You can use the operator panel
System Settings
screen to configure the following system-wide settings:
•
Touch screen audio enable
— A beep sound occurs each time you select a button on the operator
panel. The beep sound can be disabled or enabled at any time by selecting the
Touch screen
audio enable
checkbox.
•
User session timeout (minutes)
— The library automatically logs out a user or administrative user
when the library has detected no activity for 30 minutes. You can adjust the user session time by
entering a numeric value in the
User session timeout (minutes)
text box. Valid user session times
are 15 minutes to 480 minutes.
•
Unload assist
— allows you to specify whether the library should automatically eject cartridges
from tape drives. When the setting is enabled, the library will assist with tape drive unload
operations in the event that a tape drive is not unloaded by a host command. When the setting is
disabled, the library will not assist with tape drive unload operations and reject a move request from
a tape drive, if the cartridge is not already unloaded. The
Unload assist
setting is enabled by
default.
•
Logical SN addressing enable
— The library uses the actual tape drive serial numbers by default.
Selecting the
Logical SN addressing
enable
check box enables the library to assign logical serial
numbers to all tape drives in the library. Specifically, the library assigns a logical serial number to a
tape drive in a specific location, not the serial number of the particular tape drive. If the tape drive
is then replaced by another tape drive in the same library location, the logical serial number remains
the same. From the host application's perspective, the replacement tape drive is the same as the
original.
CAUTION
If you change the logical serial number addressing setting, you must power
cycle the library (perform a shutdown and press the power button) or
remove power from each tape drive for the change to take effect.
Summary of Contents for Storage Library T128
Page 1: ...USER S GUIDE 433568 01 ...
Page 8: ...viii Contents ...
Page 10: ...x Tables ...
Page 12: ...xii Figures ...
Page 28: ...16 Description ...
Page 40: ...28 Understanding the User Interface ...
Page 80: ...68 Running Your Library ...
Page 84: ...72 Getting Information ...
Page 138: ...126 Installing Removing and Replacing ...
Page 164: ...152 Installing Removing and Replacing ...
Page 174: ...162 Troubleshooting ...
Page 178: ...166 Working With Cartridges and Barcodes ...
Page 184: ...172 Specifications ...
Page 192: ...180 Glossary ...