Chapter C
Chapter C
Maintenance Mode
136
W301-0411E
6.2 Connector
6.2.1 Removing and attaching the connector
contact
NOTICE
The connector contacts are fixed to the connectors
by double-locking mechanism.
Follow the procedure below when removing and
attaching the connector contacts.
The following description is based on the
manufacturer AMP's instruction sheet.
AMP connector type
Documentation
No. of AMP
instruction
sheet
Part No. of
contact
extraction tool
.070 Multi-lock
connector (Mark )
412-5520 755430-2
.040 Multi-lock
connector (Mark )
411-5883 755430-1
.040 Multi-lock
connector (Mark )
412-5475-1
.040
Ⅱ
Multi-lock
connector (Mark )
411-5760-2 715131-1
The part Nos. of the contact extraction tools are
designated by AMP.
2.1.1 AMP.070 Multi-lock connector (Mark )
Insertion of Contact
1. Insert the receptacle properly with its seam side
up (for both upper and lower cavities) into the
housing with its locking side up. Please do not
force to insert; make sure the direction is correct.
2. Please make sure that the contact is perfectly
locked with the housing until it clicks. Please
make it a rule to check the locking by gently
pulling forward the contact after insertion.
3. In case the contact must be pulled out again,
please care about the deformation of contact.
[Refer to contact extraction tool(755430-2)
instruction sheet.]
4. Doublelock immediately after insertion of contact.
Otherwise it might be damaged in carrying the
harness due to doublelock catching things.