54
W301-0411E
Chapter B
Chapter B
User Mode
4.5.5 Fuel Consumption History Display
The fuel consumption history is displayed.
1. Hoist down a load and set each operation lever and
pedal to the neutral position.
2. Select the fuel consumption history icon, and then
push the < > key (set).
•
The screen for fuel consumption history appears.
3. The display changes when the < > key (display
change) is pushed.
•
The fuel consumption history is shown in either a
bargraph or number.
•
The items shown on the numeric display screen are
as follows.
G(N) ......... Fuel consumption during standby (gallon)
G(D) ......... Fuel consumption during crane operation
(gallon)
h/G ......... Fuel consumption ratio during crane
operation (hour/gallon) You can change
the unit of fuel consumption ratio in h/G
(hour/ gallon) or G/h (gallon/hour) by
pushing F2 (unit change) key.
The measurements restart when < > key
(reset) is pushed. The previous records are
moved down by pushing < > key (reset). 6
previous records including the current rate
are displayed.
Push < > key (exit) to exit the history display. The pop-up window closes and the AML returns to the
crane operation state.
The fuel consumptions of G(N) and G(D) include when the crane is operated without outriggers (when
traveling).
Fig. 4.5.4