Chapter A
Chapter A
Components of AML System
19
W301-0411E
CN5 connector
Pin No.
Name
(Data No. #---)
Signal names and functions
5 Do5+
(#17802-122)
- Signal name: Tactile type drum indicator (Main)
Interlocked with the drum indicator LED, output is performed to the tactile type drum indicator.
6 Do6+
(#17802-123)
- Signal name: Tactile type drum indicator (Aux.)
Interlocked with the drum indicator LED, output is performed to the tactile type drum indicator.
7 Do7+
(
#17802-132)
- Signal name: Jib set output
Improves the winch capacity when in the jib set status.
8 Do8+
(#17802-124)
-Signal name: AML normal output (Normal: 24V output, Abnormal: 0V)
Detects the reckless driving of task, and outputs the result.
9 Do9-
(Spare)
(
#17802-148)
[GR-1000XL-2]
- Signal name: Main winch high-speed hoist-down
Output to drive the high-speed hoist-down valve of main winch
10 Do10-
(Spare) [GR-750XL-2]
(
#17802-149)
[GR-1000XL-2]
- Signal name: Auxiliary winch high-speed hoist-down
Output to drive the high-speed hoist-down valve of auxiliary winch
11 Do11-
(Spare) [GR-750XL-2]
12 Do12-
(
#17802-12)
- Signal name: Buzzer output (AML warning)
Controls the external buzzer depending on the load moment ratio.
There are two outputs: intermittent output for when notice is made and continuous output for
when limit is reached.
Output condition: Load moment ratio of 90% or more and less than 100%; intermittent
output with 0.8 s interval
Load moment ratio of 100% or more: Continuous output
Output when condition(s) is/are met: OFF output
13 Do13-
(#17802-38)
- Signal name: Buzzer output (twoblocking warning)
Twoblocking warning buzzer sounds when the twoblocking status is reached.
Output when in twoblocking status: ON output