Chapter C
Chapter C
Maintenance Mode
132
W301-0411E
4.4.3 AML Internal Abnormality (System Abnormality)
±
: All the operations are stopped. (AML automatic stop output OFF)
Error
code
Error name
Description
Crane
operation
ROM check sum
abnormality
An abnormality has occurred to the ROM check sum.
±
-
Cause: Incorrect flash memory writing, memory malfunction
Remedy: Perform inspection for the above possible cause.
RAM abnormality
RAM writing/readout cannot be performed normally.
±
E3002
Cause: Malfunction due to noise and others, board malfunction
Remedy: Perform inspection for the above possible cause.
E3003
CPU or DMAC address error has occurred.
E3004
CPU has executed an abnormal command, including slot illegal
instruction.
E3005
CPU exception
An exception processing has been activated which is not executed in
normal cases.
±
Cause: Runaway due to noise and others, board malfunction
However, even in the normal status, this may be stored at turning ON/OFF of power.
Remedy: Perform inspection for the above possible cause.
Internal power
supply abnormality
An abnormality has occurred to the analog power supply voltage.
±
E3006
Cause: Board malfunction, detector malfunction, short circuit in wiring to detector
Remedy: Perform inspection for the above possible cause.
Flash memory
abnormality
The area that stores the adjustment value is destructed.
Re-adjustment is required.
c
E3007
Cause: Board malfunction, malfunction due to noise and others.
Unless the error data is erased, the message remains.
Remedy: Perform inspection for the above possible cause.
Task execution
abnormality
Runaway has occurred to the I/O related program.
±
E3008
Cause: Malfunction due to noise and others, board malfunction
Remedy: Perform inspection for the above possible cause.