39
W301-0411E
Chapter B
Chapter B
User Mode
3.2 Warning Code and Crane Model Comparison Table
Table
3.2.1
●
:
Stop Warning Code,
:
Warning Code
Code Cause GR-750XL-2
GR-1000XL-2
W0001
Right front outrigger beam retraction
○
○
W0002
Right rear outrigger beam retraction
○
○
W0003
Left front outrigger beam retraction
○
○
W0004
Left rear outrigger beam retraction
○
○
W0005
Boom angle value becomes out of specified range
W0006
Improperly inserted jib lock pin
W0007
Stop at swing angle limit
●
●
W0012
Rear stability auto. stop range
W0013
Over-front detection switch is defective
○
○
W0015
Twoblocking condition
(When Anti-twoblock stop function is cancelled)
○
○
W0016
State 1 is not applied
(Outrigger, Swing angle, C/W, combinations)
○
○
W0017
State 2 is not applied
(Boom and Jib combination)
○
○
W0018
Boom full retraction switch 1 faulty
○
○
W0019
Boom full retraction switch 2 faulty
○
○
W0020
Boom full retraction switch 3 faulty
W0021
Boom full retraction switch 4 faulty
W0022
Jib full retraction switch 1 faulty
W0023
Stopped at 100% of crane performance
●
●
W0024
Stop due to twoblocking (overwind)
●
●
W0025
Stopped due to backward stability
●
●
W0026
Stopped at upper boom angle limit restriction
●
●
W0027
Stopped at lower boom angle limit restriction
●
●
W0028
Stopped at lifting height restriction
●
●
W0029
Stopped at load radius restriction
●
●
W0034
Stopped by main winch over-unwinding
prevention device (Europe spec.)
●
●
W0035
Stopped by aux. winch over-unwinding
prevention device (Europe spec.)
●
●
W0040
AML override sw “ON” condition (EN13000 spec.)
W0042
Right swing restriction limit
●
●
W0043
Left swing restriction limit
●
●
W0044
Jib stowed condition
W0054
Stopped by elevating cylinder stroke end (Ret.)
●
●
W0055
Stopped by elevating cylinder stroke end (Ext.)
●
●
W0056
Swing operation is dangerous
○
○
W0057
Right front outrigger state change
○
○
W0058
Right rear outrigger state change
○
○
W0059
Left front outrigger state change
○
○
W0060
Left rear outrigger state change
○
○
W0078
Altered counterweight state
○
○
W0106
Elevating speed is reducing
○
○
W0107
Telescoping speed is reducing
W0108
Swing speed is reducing
○
○
W0121
Stopped at elevating cylinder stroke end
●
●
W0122
Out of working range
W0123
During jib stowing
W0124
Stopped at limit range of boom with jib
●
●
W0189
Boom angle out of specified range for hook-in
W0190
Auto. stopped at critical range
W0191
Auto. stop override sw is defective (STD spec.)
W0197
Boom interference condition
○
○
W0198
Special lifting performance
W0214
Stopped due to Tension rod interference
W0215
Boom length detection is inconsistent
W0219
Stopped due to boom full extension
W0999
Back-up battery running down
○
○