Chapter A
Chapter A
Components of AML System
21
W301-0411E
CN5 connector
Pin No.
Name
(Data No. #---)
Signal names and functions
16 Do16-
(
#17802-11)
- Signal name: External indicator lamp (100% or more, red)
When the load moment ratio is 100% or more, the red external indicator lamp lights.
Output condition:
(1) or (2) or (3)
(1): Load factor exceeds 100%.
(2) 100% cancel indication (Di6) is "Canceled" status.
(3): Twoblocking cancel indication (Di5) is "Canceled" status.
When in the boom operation with jib
elected
(during main operation with jib
elected
), the
red external indicator lamp lights when the
load moment ratio described below is
reached.
(#20803)
Output
Outrigger
extension
width
GR-750XL-2 GR-1000XL-2
Maximum
extension
88
%
or more
94
%
or more
Middle
extension 2
87
%
or more
93
%
or more
Middle
extension 1
80
%
or more
92
%
or more
Output when condition is met: OFF output