2.1.2 AMP.040 Multi-lock connector (Mark )
Insertion of Contact
1. Insert the receptacle properly with its seam side
up (for both upper and lower cavities) into the
housing with its locking side up. Please do not
force to insert; make sure the direction is correct.
2. Please make sure that the contact is perfectly
locked with the housing until it clicks. Please
make it a rule to check the locking by gently
pulling forward the contact after insertion.
3. In case the contact must be pulled out again,
please care about the deformation of contact.
[Refer to contact extraction tool(755430-1)
instruction sheet.]
4. Doublelock immediately after insertion of contact.
Otherwise it might be damaged in carrying the
harness due to doublelock catching things.
Double lock
1. After the insertion of contact into the housing,
doublelock it (hinge type). Please make sure to
lock all of them.
2. Increase of Contact Keeping Strength can be
expected by doublelocking.
3. Releasing Doublelock:
Refer to contact extraction tool(755430-1)
instruction sheet.
"Please obey the authorized instruction to
release,otherwise the housing could be damaged.
Please release it properly."
Harness Checker
1. Please refer to the Fig. below to check the current
running of assembled harness.
“Use of Current Checker of Spring Pin is preferable.