Chapter C
Chapter C
Maintenance Mode
125
W301-0411E
Error
code
Error name
Description
Crane
operation
Transmitter 2 defect
Transmitter connected with port 2 has detected an internal
abnormality.
¯
E1006
Cause: Transmitter malfunction. Refer to transmitter repair manual.
Remedy: Replace the defective transmitter.
Transmitting data
error at serial port 1
Transmitter connected with port 1 issued a notification that an
abnormality is present in the data received from the AML.
¯
E1007 Cause: Communication line from AML to transmitter is open. Radio wave interference, device
malfunction
Remedy: Turn off any device which is emitting strong noise. Check the signal wire for poor
connection. Repair or replace the wiring as appropriate.
Transmitting data
error at serial port 2
Transmitter connected with port 2 issued a notification that an
abnormality is present in the data received from the AML.
¯
E1008 Cause: Communication line from AML to transmitter is open. Radio wave interference, device
malfunction
Remedy: Turn off any device which is emitting strong noise. Check the signal wire for poor
connection. Repair or replace the wiring as appropriate.
Receiving data error
at serial port 1
The AML cannot receive the data correctly from the transmitter
connected with port 1.
¯
E1009 Cause: Communication line from AML to transmitter is open. Radio wave interference, device
malfunction
Remedy: Turn off any device which is emitting strong noise. Check the signal wire for poor
connection. Repair or replace the wiring as appropriate.
Receiving data error
at serial port 2
The AML cannot receive the data correctly from the transmitter
connected with port 2.
¯
E1010
Cause: Communication line from AML to transmitter is open. Radio wave interference, device
malfunction
Remedy: Turn off any device which is emitting strong noise. Check the signal wire for poor
connection. Repair or replace the wiring as appropriate.
Transmitter type
improper
(serial port 1)
The type of transmitter connected with port 1 is incorrect.
¯
E1011
Cause: Transmitter malfunction, incorrect connection
Remedy: Connect a proper transmitter to the serial port.