4-24
SPARC Enterprise Mx000 Servers XSCF User’s Guide • August 2009
2. Use the
setdualpowerfeed
(8) command to enable or disable the dual power
feed of this system.
3. Confirm the new setting, and if it is correct, turn off the input power and then
turn on to apply the specified configuration. When you enabled the dual power
feed mode, you can apply the configuration by executing the
rebootxscf
(8)
command.
4. Confirm whether the setting is valid after turning off/on the input power.
<Example 1> Enabling the dual power feed.
XSCF>
setdualpowerfeed -s enable
disable -> enable
NOTE: Dual power feed will be enabled the next time the platform
is powered on.
<Example 2> Disabling the dual power feed.
XSCF>
setdualpowerfeed -s disable
enable -> disable
NOTE: Dual power feed will be disabled the next time the platform
is powered on.
XSCF>
showdualpowerfeed
disable -> enable
NOTE: Dual power feed will be enabled the next time the platform
is powered on.
XSCF>
showdualpowerfeed
Dual power feed is enabled.
Summary of Contents for Sun SPARC Enterprise M3000
Page 4: ......
Page 52: ...1 26 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Page 252: ...4 32 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Page 272: ...5 20 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Page 348: ...A 6 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Page 366: ...C 6 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...
Page 398: ...Index 6 SPARC Enterprise Mx000 Servers XSCF User s Guide August 2009 ...