7 Teleservice Application Framework
User Manual
203/374
Information Flow
Input Information
Parameter
Range
Description
opt_DBusInstance
T_DBUS_Util
holds all D-Bus information
opcn_LogJobName
maximum
MAX_DL_NAME_LENGTH
pointer to log job name
ou32_LoggingBufferSize
maximum
MAX_DL_BUFFER_SIZE
0 means buffer disabled
Otherwise number of log entries to buffer
Structure T_DBUS_Util
typedef struct
{
DBusConnection* pt_dbus_conn;
// D-BUS connection instance
charn acn_myNameString[128];
// Name of the application, Don't use any
special
// characters, white spaces or new lines!
charn acn_myVersion[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myStatus[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myAddInfo[512];
// Additional value (for HELLO) signal (opt.)
sint32 s32_myTriginterval;
// Time interval when the ysysd
// expects to be triggered
charn acn_myCMDOnWatchdog[2048];
// Bash cmd that must be executed
// by the ysysd in case no
// trigger signal occurred in time.
} T_DBUS_Util;
Output Information
Return Value
Description
C_NO_ERR
Function executed without error
buffered trigger was successfully set
C_COM
D-Bus communication error
C_UNKNOWN_ERR
NULL pointer error or wrong parameters
C_NOACT
Error occurs because:
log job name is invalid
trigger time interval to short
data logger configuration does not exist,
DLC file is corrupt
Summary of Contents for TC1
Page 1: ...TC1 User Manual Version of this document V1 00r0 ...
Page 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Page 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Page 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Page 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...