7 Teleservice Application Framework
User Manual
90/374
Section: Watchdog handling
# The hardware watchdog path ensures that the user space scheduling is running properly.
# Max. path length is 255
# If the path is deactivated or no path is set, an error message will be put on stdout.
watchdog_path /dev/watchdog
# Watchdog interval is set in seconds. Min. 0 / max. 0xFFFFFFFF, recommended min. 30s /
max. is 100s, default interval is 30s
# If no interval is set, then the default interval of 30s will be set.
watchdog_interval 30
Section: Shutdown run time path
# The shutdown run time path includes the run time in seconds after shutdown (ignition
off). When the ignition pins
# goes off, the controller (TC1 can keep on running for a certain amount of time. User
space applications can also
# set the desired time.
# Max. path length 255
# If the path is deactivated or no path is set, an error message will be put on stdout.
runtimefile_path /tmp/sdruntime
Section: Run time interval
# The run time interval is in seconds. Min. 0, Max. recommended 10s, default interval 5s
# If no interval is set, the default interval will be set.
run_interval 5
Section: DPlus inversion
# On some devices it is necessary to invert the dplus pin. Per default, the
# inversion of the pin of off (default value : 0) To activate the inversion,
# set the value to 1
dplus_inv 0
NOTE:
This file will be set by the boot up script at boot time, but it can be overwritten by applications
anytime before the ignition goes off.
Summary of Contents for TC1
Page 1: ...TC1 User Manual Version of this document V1 00r0 ...
Page 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Page 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Page 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Page 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...