7 Teleservice Application Framework
User Manual
228/374
7.3.6.4.3
ylogd_trigger_buffered_log
Function Description
sint32 ylogd_trigger_buffered_log(const T_DBUS_Util * const opt_DBusInstance, const charn *
const opcn_DataLoggerName)
The function causes an activated, buffered log job to flush its ring buffer to the log file and then continue
operation as normal.
Information Flow
Input Information
Parameter
Range
Description
opt_DBusInstance
T_DBUS_Util
holds all D-Bus information
opcn_DataLoggerName
maximum
MAX_DL_NAME_LENGTH
pointer to the name of the logger file
Structure T_DBUS_Util
typedef struct
{
DBusConnection* pt_dbus_conn;
// D-BUS connection instance
charn acn_myNameString[128];
// Name of the application, Don't use any
special
// characters, white spaces or new lines!
charn acn_myVersion[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myStatus[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myAddInfo[512];
// Additional value (for HELLO) signal (opt.)
sint32 s32_myTriginterval;
// Time interval when the ysysd
// expects to be triggered
charn acn_myCMDOnWatchdog[2048];
// Bash cmd that must be executed
// by the ysysd in case no
// trigger signal occurred in time.
} T_DBUS_Util;
Output Information
Return Value
Description
C_NO_ERR
file / files was / were found and deleted
C_CONFIG
flag parameter not correct, log job not buffered
C_UNKNOWN_ERR
NULL pointer
C_RANGE
opcn_DataLoggerName out of range
Summary of Contents for TC1
Page 1: ...TC1 User Manual Version of this document V1 00r0 ...
Page 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Page 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Page 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Page 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...