Server
Header file: "Server_handler.h"
7.3.10.1 Introduction
The yserver daemon of the TAF library is a component that provides functionality for immediate NextJob.job file
request.
7.3.10.2 eGPRSComServer specific commands
The eGPRSComServer specific commands manage the data exchange between a TC1 and a GPRS
communication server (GPRS ComServer). If not included in a data section, the parameters are stored in ASCII
format in the NextJob.job file.
FWSW
– Set wakeup cycle time
Syntax of command:
FWSW;<wakeup_cycle>
Syntax of response:
FWSW;<error_code>
Description:
Set a new wakeup cycle time. At this interval the TC1 requests a new NextJob.job from the ComServer.
Parameter:
Input:
Variable
Variable Type
Description
wakeup_cycle
uint32
Wakeup cycle time in seconds
NOTE:
For more information about the NextJob.job mechanism contact Sensor-Technik Wiedemann GmbH
Support.