7 Teleservice Application Framework
User Manual
201/374
7.3.6.2.5
ylogd_set_trigger_time
Function Description
sint32
ylogd_set_trigger_time (const T_DBUS_Util *const
opt_DBusInstance,
const charn *
const opcn_LogJobName, const uint32 ou32_LoggingInterval)
The function sets the time interval between two data logging records. The logging interval ou32_Logging has to
be greater than or equal to the sample time. The sample time is set in the function ylogd_create_log_job (see
"
Information Flow
Input Information
Parameter
Range
Description
opt_DBusInstance
T_DBUS_Util
holds all D-Bus information
opcn_LogJobName
maximum
MAX_DL_NAME_LENGTH
pointer to the data log job name
ou32_LoggingInterval
1 .. uint32
includes trigger time in ms
value has to be >= sample time
parameter from ylogd_create_log_job
(see "
" on page
Structure T_DBUS_Util
typedef struct
{
DBusConnection* pt_dbus_conn;
// D-BUS connection instance
charn acn_myNameString[128];
// Name of the application, Don't use any
special
// characters, white spaces or new lines!
charn acn_myVersion[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myStatus[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myAddInfo[512];
// Additional value (for HELLO) signal (opt.)
sint32 s32_myTriginterval;
// Time interval when the ysysd
// expects to be triggered
charn acn_myCMDOnWatchdog[2048];
// Bash cmd that must be executed
// by the ysysd in case no
// trigger signal occurred in time.
} T_DBUS_Util;
WARNING:
If the trigger time is not set, the log mechanism can not be started. The only exception for this rule is
simple event triggered logging. In that case the trigger time will be automatically set to the sample
time.
Summary of Contents for TC1
Page 1: ...TC1 User Manual Version of this document V1 00r0 ...
Page 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Page 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Page 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Page 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...