7 Teleservice Application Framework
User Manual
213/374
// expects to be triggered
charn acn_myCMDOnWatchdog[2048];
// Bash cmd that must be executed
// by the ysysd in case no
// trigger signal occurred in time.
} T_DBUS_Util;
Output Information
Return Value
Description
C_NO_ERR
Function executed without error
buffered trigger was successfully set
C_COM
D-Bus communication error
C_UNKNOWN_ERR
NULL pointer error or wrong parameters
C_NOACT
Error occurs because:
logger job name is invalid
log management has not been configured yet
C_RANGE
opcn_LogJobName is out of range
7.3.6.2.11 ylogd_activate_log_job
Function Description
sint32
ylogd_activate_log_job (const T_DBUS_Util *const
opt_DBusInstance,
const charn *
const opcn_LogJobName, const uint32 ou32_OnOff)
The function starts (ou8_OnOff != 0) and stops
(ou8_OnOff == 0)
the log job opcn_LogJobName.
Information Flow
Input Information
Parameter
Range
Description
opt_DBusInstance
T_DBUS_Util
holds all D-Bus information
opcn_LogJobName
maximum
MAX_DL_NAME_LENGTH
pointer to the log job name which shall be
activated
ou32_OnOff
0 = Off , 1 = On
includes the OnOff flag (0 = off 1 = on)
Summary of Contents for TC1
Page 1: ...TC1 User Manual Version of this document V1 00r0 ...
Page 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Page 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Page 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Page 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...