7 Teleservice Application Framework
User Manual
205/374
Parameter
Range
Description
opcn_LogJobName
maximum
MAX_DL_NAME_LENGTH
pointer to the log job name
opcn_DatapoolName
maximum
MAX_DP_NAME_LENGTH
pointer to the data pool name
opcn_ListName
maximum
MAX_DP_NAME_LENGTH
pointer to the variable list name
opcn_VariableName
maximum
MAX_DP_NAME_LENGTH
pointer to the variable name
opcn_Logic
maximum
MAX_DL_LOGIC_LENGTH
pointer to the logical operator like '<=', '>=', '!='
and '=='
ou32_Hysteresis
uint32
pointer to the hysteresis of the variable we
expect to log
ou32_Threshold
uint32
pointer to the logging threshold for the variable
we expect to log
opcn_Concatenation
maximum
MAX_DL_CONC_LENGTH
pointer to concatenation options like 'AND', 'OR'
and 'EXOR'
Structure T_DBUS_Util
typedef struct
{
DBusConnection* pt_dbus_conn;
// D-BUS connection instance
charn acn_myNameString[128];
// Name of the application, Don't use any
special
// characters, white spaces or new lines!
charn acn_myVersion[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myStatus[128];
// Additional value (for HELLO) signal (opt.)
charn acn_myAddInfo[512];
// Additional value (for HELLO) signal (opt.)
sint32 s32_myTriginterval;
// Time interval when the ysysd
// expects to be triggered
charn acn_myCMDOnWatchdog[2048];
// Bash cmd that must be executed
// by the ysysd in case no
// trigger signal occurred in time.
} T_DBUS_Util;
Output Information
Return Value
Description
C_NO_ERR
Function executed without error, event condition was set successfully
Summary of Contents for TC1
Page 1: ...TC1 User Manual Version of this document V1 00r0 ...
Page 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Page 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Page 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Page 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...