7 Teleservice Application Framework
User Manual
222/374
THRESHOLD=1000
CONCATENATION=OR
[SAVECONDITIONS]
LOG_MECHANISM=1
TRIGGERTIME=0
NUMSAVECONDITIONS=0
7.3.6.3.4
Add save condition to DLC file
The following variable objects have to be added to the DLC file in order to add a save condition:
Variable objects
Parameter
Description
[SAVECONDITION1-
n]
Start tag which contains the actual number of the save condition
VARIABLENAME
Name of the save condition variable
DATAPOOL
Name of the data pool, which contains the list and the save condition variable name
LIST
Name of the list which contains the save condition variable name
LOGIC
<=, >=; ==; !=
HYSTERESIS
Hysteresis
THRESHOLD
Threshold
CONCATENATION
AND, OR, XOR
Explanation
This means that a save condition is defined that is concatenated with the previous event conditions result. A
variable to be tested is defined by: DATAPOOL, LIST and VARIABLENAME.
The testing logic is defined by LOGIC which can be "!=", "==", "<=", ">="
The value the variable is tested against is defined by:
TH/- HYSTERESIS
If there are more than one conditions to be tested, then it's result is logically linked with its previous result by
CONCATENATION.
CONCATENATION can be "AND", "OR", XOR".
NOTE:
See also How the logger mechanism works (see "
Summary of Contents for TC1
Page 1: ...TC1 User Manual Version of this document V1 00r0 ...
Page 25: ...5 Hardware User Manual 25 374 5 2 2 Block Diagram Variant TC1 WIFI ...
Page 34: ...5 Hardware User Manual 34 374 5 6 Housing Connector Top view and side view Bottom View ...
Page 125: ...7 Teleservice Application Framework User Manual 125 374 TAF overview ...
Page 190: ...7 Teleservice Application Framework User Manual 190 374 How the logger mechanism works ...