Operating & Maintaining the Eden350V 3D Printer
6–38
DOC-03050 Rev. A
To clean the print heads:
¾
Refer
to
To print calibration samples:
1. From
the
Options
menu,
select
Weight Test
and
one
of
the
following:
•
HQ Weight Test
(to
calibrate
heads
for
High
Quality
printing)
•
HS Weight Test
(to
calibrate
heads
for
High
Speed
printing)
Figure 6-52: Printing print-head calibration samples
2. Set
the
printer
to
on
‐
line
mode.
Figure 6-53: Printer in on-line mode
The
printer
prints
eight
calibration
patches
on
the
build
tray.
To examine the calibration samples:
¾
Use
the
Missing
Nozzles
Ruler
to
determine
the
number
of
clogged
(“missing”)
nozzles
the
printed
patches.
Clogged
nozzles
are
seen
in
the
samples
as
missing
rows
of
printed
material.
When
you
match
the
gap
in
the
printed
sample
with
a
line
on
the
Missing
Nozzles
ruler,
the
number
on
the
ruler
next
to
the
line
indicates
the
number
of
missing
rows.
To accurately test and calibrate the print heads, they must be clean.