![Stratasys Eden350V User Manual Download Page 163](http://html1.mh-extra.com/html/stratasys/eden350v/eden350v_user-manual_1383542163.webp)
DOC-03050 Rev. A
6–57
Eden350V User Guide
Replacing the
Odor Filter
If
the
printer
exhaust
is
not
connected
to
an
external
ventilation
system,
a
built
‐
in
activated
‐
carbon
filter
removes
odors
from
printing
materials.
This
filter
should
be
replaced
regularly
(as
necessary)
to
keep
your
working
environment
pleasant.
For
more
information,
contact
your
Stratasys
service
provider.
Replacing the
UV Lamps
The
UV
lamps
used
for
curing
models
have
a
long,
but
limited,
working
life.
You
can
test
and
adjust
their
effective
power
with
the
UV
Calibration
wizard
(see
If
you
need
to
replace
a
UV
lamp,
follow
these
instructions:
1. Make
sure
the
printer
is
in
offline
mode.
Figure 6-93: Offline mode indicator (red)
The
online/offline
button
at
the
bottom
of
the
printer
interface
should
be
red.
If
not,
click
it
to
switch
the
printer
to
offline
mode.
2. Start
the
UV
Lamp
Replacement
wizard
from
the
Options
menu
(see
3. Make
sure
that
the
build
tray
is
empty,
and
confirm
this
in
the
wizard
screen.
Then,
close
the
printer
cover
and
click
Next
.
Figure 6-94: “Empty tray” confirmation screen
The
axes
move
to
the
“home”
position.
WARNING:
Before continuing, make sure that the safety interlock is not
defeated, and that the lamp is not hot.
Summary of Contents for Eden350V