t a glance
For fully automatic heating
water heating up to +60 °C flow
temperature
temperature range for the wPw
M inlet:
water temp.+7 °C to +20 °C
Comprises all components
required for its function and
safety
sound-insulated construction and
sound attenuating materials in
the casing components
Corrosion-protected through zinc-
plated or stove enamelled casing
components
For installation in rooms free
from the risk of frost (no external
installation)
Central control of the heating
system and safety functions
through the heat pump manager
wPMw ii
test symbol of independent test
bodies (see type plate)
Contains HCFC and CFC-free
r410A refrigerant
Can be operated with heating
return water up to +75 °C (dual-
mode operation)
Appliance description
water | water heat pump for internal
installation of a set combination. the
heat pump drive unit is equipped
with an hermetically sealed
compressor, soft starter, condenser,
evaporator (made completely from
stainless steel), safety equipment
such as a high/low pressure limiter,
and a frost protection facility.
the stainless steel evaporator is
corrosion-resistant to all types of
groundwater that contain no more
than 300 mg/l chloride and 0.5 mg/l
free chlorine. the heat pump is filled
with HCFC and CFC-free refrigerant
r410A.
Function
environmental energy is extracted
by the heat exchanger on the heat
source side (evaporator). Any energy
extracted is transferred, together with
the energy drawn by the compressor
drive, to the heating water by a
heat exchanger on the heating
water side (condenser). subject
to the heating load, the heating
water can be heated to between
+15 °C and +60 °C. the correct and
professional implementation of the
heat source system is a must for
a perfect operation. implement a
well installation in accordance with
the technical documentation and
manufacturer's details.
Sets
when the heating output of the
largest heat pump is inadequate, two
wPw M heat pumps are controlled as
set 20 to 36.
watEr | watEr HEat pUmpS wpw 13/18/22 m
Safety and quality
Summary of Contents for Heat pumps
Page 97: ...97 www stiebel eltron COM Notes ...
Page 110: ...110 www stiebel eltron COM Notes ...
Page 116: ...116 www stiebel eltron COM Notes ...
Page 124: ...124 www stiebel eltron COM Notes ...
Page 182: ...182 www stiebel eltron COM Notes ...
Page 183: ...183 www stiebel eltron COM Accessories for heating heat pumps ...