148
www.stiebel-eltron.CoM
InStallatIon wpf 10/13/16 m
Conditions at the heat pump (type
WPF.M) installation location
the room where the wPF.M is to be
installed must meet the following
conditions:
Free from the risk of frost
load-bearing floor (weight of the
wPF.M approx. 130 kg)
Horizontal, level and solid floor,
as the appliance feet on the heat
pump are non-adjustable
For a quiet heat pump operation
on floating screeds, recess the
screed and the anti-vibration
insulation around the installation
location of the heat pump
the installation room must not
be subject to a risk of explosions
arising from dust, gases or
vapours
when installing the wPF.M in a
boiler room together with other
heating equipment ensure, that
the operation of other heating
equipment will not be impaired.
Acoustic emissions
never install the heat pump
immediately below or adjacent to
bedrooms. Good sound insulation
can be achieved by using a concrete
plinth with a rubber mat underneath
the appliance. insulate pipes through
walls and ceilings against structure-
borne noise transmission. Make the
brine and heating system connections
using flexible pressure hoses.
Installation of the brine | water heat pump WPF.M
1
Heat pump
2
impact sound insulation
3
Floating screed
screed and impact sound
insulation. recess
if provided.
Connection dimensions WPF M in mm
1
brine outlet
2
brine outlet
4
Heating flow
5
Heating return
6
safety assembly connection
7
Cold water connection
8
Cable entries
Summary of Contents for Heat pumps
Page 97: ...97 www stiebel eltron COM Notes ...
Page 110: ...110 www stiebel eltron COM Notes ...
Page 116: ...116 www stiebel eltron COM Notes ...
Page 124: ...124 www stiebel eltron COM Notes ...
Page 182: ...182 www stiebel eltron COM Notes ...
Page 183: ...183 www stiebel eltron COM Accessories for heating heat pumps ...