![STIEBEL ELTRON Heat pumps Technical Manual Download Page 105](http://html1.mh-extra.com/html/stiebel-eltron/heat-pumps/heat-pumps_technical-manual_1376699105.webp)
105
www.stiebel-eltron.CoM
powEr SUpply wpl 14 Ht
Power supply
You may need to notify your local
power supply company of the heat
pump connection.
All electrical installation work,
particularly earthing measures, must
be carried out in accordance with
local and national regulations and
the requirements of your local power
supply company. the connection must
comply with the power connection
diagram. For this, also observe the
installation instructions for the heat
pump manager wPM ii.
Electrical specification of the heat pump
Heat pump
Power
consumption
kw
Max. operating
current
A
starting
current r start
A
Power cable
mm²
Fuse
protection
A
wPl 14 Ht
6.2
19.3
<30
5 x 2.5 *
C 16A all poles
* Cable cross-section acc. to type of routing (observe VDe 0298-4 [or local regulations])
WPL HT 3-phase
3/n/Pe
230V ~ 50Hz
Domestic meter
Control phase l
w/o power-oFF
period
Control phase l´
with power-oFF
period
3/n/Pe
400V ~ 50Hz
Heat pump meter
Pulse
Pulse input wP
l
Power supply
t (ww)
temperature sensor, DHw
n
Power supply
t(A)
outside temperature sensor
Pe
Power supply
t(MK)
temperature sensor, mixer circuit
imp.
Pulse
Fern1
remote control
MKP
Mixer circuit pump
Fern3
remote control
eVU
enable signal
H
bUs high
M(A)
Mixer open
l
bUs low
M(Z)
Mixer closed
–
bUs ground
ZKP
DHw circulation pump
+
bUs +
Summary of Contents for Heat pumps
Page 97: ...97 www stiebel eltron COM Notes ...
Page 110: ...110 www stiebel eltron COM Notes ...
Page 116: ...116 www stiebel eltron COM Notes ...
Page 124: ...124 www stiebel eltron COM Notes ...
Page 182: ...182 www stiebel eltron COM Notes ...
Page 183: ...183 www stiebel eltron COM Accessories for heating heat pumps ...