HEatIng SyStEm connEctIon wpf 10/13/16 m
Heating system connection
install the heat utilisation system
(HUs) in accordance with the design
documentation. For standard heating
systems integrate the heat pump
into the water side according to
standard circuits (see appendix).
Prior to connecting the heat pump,
check the heating system for leaks,
flush it thoroughly, then fill and vent
it thoroughly. ensure the correct
connection of the heating flow and
return. Flexible pressure hoses are
recommended to reduce structure-
borne noise transmission on the water
side. the required circulation pump
is integrated into the heat pump. the
adjacent table shows the pipe cross-
section. Provide thermal insulation in
accordance with local regulations.
WPF M with buffer cylinder SBP 200 and DHW heating
Heat pumps type WPF.M without integral circulation pump
Heat pump
Flow rate
Circulation pump
Copper pipe
type
m³/h
type
mm
wPF 10 M
0.9
UP 26-60
28 x 1.5
wPF 13 M
1.2
UP 25 - 60
28 x 1.5
wPF 16 M
1.4
UP 25-80
28 x 1.5
Summary of Contents for Heat pumps