SETUP Area
QB Expert Alpha Controller
36
Torque Recovery
Creates a Torque Control/ Angle Monitor Strategy step AFTER the Audit step and will make
the Torque Recovery step the Audit step. The torque parameters of the Torque Recovery
step are the same as the Audit step. Sets Merge Torque to Yes. Sets Accumulate Angle to
Yes. Sets Torque Display to Final for both steps.
Relaxation Time
This is the value for the Delay Between Steps of the Audit step prior
to running the Torque Recovery step. The Wizard uses 0.05 seconds
as default.
Speed
The Speed of the tool’s output in Revolutions Per Minute (RPM)
during the Torque Recovery step. The Wizard uses 10 RPM as
default.
Rotation
Threshold
If the achieved angle in the Torque Recovery step exceeds the
Rotation Threshold the torque and angle values displayed and saved
are the final torque and final angle of the Torque Recovery step.
If the achieved angle in the Torque Recovery step does not exceed
the Rotation Threshold in the Torque Recovery step, the torque and
angle values displayed and saved are the final torque and final angle
of the Audit step.
The Wizard uses 0 degrees as default.
Backout
Fastener
Accommodates assembly procedures requiring partial removal of the fastener before
additional components can be added to the joint. Creates a Back off strategy Smart Step
after the Audit step. The tool stops after achieving either the angle or torque target. If
selected, this is the first step AFTER the Audit step. Options include:
Angle Target
The number of degrees of rotation the socket turns during this step.
The Wizard uses 1800˚ by default.
Torque Target
The Target Torque for this step. The Wizard uses the tool’s rated
torque as default.
Speed
The speed of the tool’s output in Revolutions Per Minute (RPM). The
Wizard uses the rated speed of the tool in RPM as default.
Fastener Release
In some fastening situations sockets become stuck on the fasteners. This step reverses
the tool and releases the socket without loosening the fastener. Creates an Angle Control
or Torque Control (AC/TC) strategy Smart Step that rotates the fastener in the opposite
direction of the Audit step. Options include:
Angle Target
The number of degrees of rotation the socket turns during this step.
The Wizard uses 50˚ by default.
Speed
The speed of the tool’s output in Revolutions Per Minute (RPM). The
Wizard uses the rated speed of the tool in RPM as default.
Max Torque
The maximum allowed torque during this step. The Wizard uses
50% of the rated torque of the tool by default.
Press the FINISH interactive menu button to close the Wizard.
AC TM
AC TC
TC AM
AC/TA
Summary of Contents for QB Expert
Page 8: ......
Page 23: ...Introduction Instruction Manual 15 ...
Page 24: ......
Page 36: ......
Page 37: ...3 QB Expert Alpha Controller Programming SETUP Area SERVICE Area ANALYZE Area ...
Page 94: ......
Page 109: ...Instruction Manual 101 ...
Page 110: ......
Page 123: ...Instruction Manual 115 Tool Operation ...
Page 124: ......
Page 132: ...Input and Output Connector QB Expert Alpha Controller 124 Inputs example ...
Page 133: ...Controller Connections Instruction Manual 125 Outputs Sourcing example ...
Page 157: ...Controller Connections Instruction Manual 149 ...
Page 158: ...MODBUS TCP QB Expert Alpha Controller 150 ...
Page 175: ...Embedded PLC Instruction Manual 167 ...
Page 176: ......
Page 183: ...Multiple Spindle Instruction Manual 175 ...
Page 184: ... QB Expert Alpha Controller 176 ...
Page 201: ...Instruction Manual 193 Maintenance ...
Page 202: ...QB Expert Alpha Controller 194 ...
Page 203: ...10 QB Expert Alpha Controller Appendix A Torsion Compensation Angle Validation ...
Page 206: ......
Page 207: ...11 QB Expert Alpha Controller Glossary ...
Page 210: ......