Controller Connections
Instruction Manual
143
Outputs
Description
*RUNDOWN
STATUS
This output will be one of two selections. The selections are the User Defined Value for the associated status of
the last fastening cycle. For example: if the last fastening cycle status was OK, and the User Defined Value for OK
is Good, then this output value is Good.
The OK User Defined Value asserts at the end of a fastening cycle when the achieved torque and angle for the
Audit step are within specified limits.
The NOK User Defined Value asserts at the end of a fastening cycle when the achieved torque and angle for the
Audit step are NOT within specified limits.
The value resets to zero (0) when the tool is commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
OK: User Defined Value
NOK: User Define Value
Spindle: Type the spindle number from which the signal comes.
*RUNDOWN TASK
This value indicates the task in which the last fastening cycle was performed. It asserts when the fastening
cycle is complete (after the IN CYCLE bit resets). The value resets to zero (0) when the tool is commanded to run
again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the signal comes.
*RUNDOWN
UNITS
This is the numeric equivalent value of the torque units of the last fastening cycle. It asserts when the fastening
cycle is complete (after the IN CYCLE bit resets). The value resets to zero (0) when the tool is commanded to run
again.
The numeric equivalent values are:
0 – NM
1 – FTLB
2 – INLB
3 – INOZ
4 – KGM
5 - KGCM
6 – NCM
7 – NDM
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the signal comes.
*RUNDOWN
YEAR
This is the year value of the last fastening cycle date. It asserts when the fastening cycle is complete (before the
IN CYCLE bit resets). The value resets to zero (0) when the tool is commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the signal comes.
Summary of Contents for QB Expert
Page 8: ......
Page 23: ...Introduction Instruction Manual 15 ...
Page 24: ......
Page 36: ......
Page 37: ...3 QB Expert Alpha Controller Programming SETUP Area SERVICE Area ANALYZE Area ...
Page 94: ......
Page 109: ...Instruction Manual 101 ...
Page 110: ......
Page 123: ...Instruction Manual 115 Tool Operation ...
Page 124: ......
Page 132: ...Input and Output Connector QB Expert Alpha Controller 124 Inputs example ...
Page 133: ...Controller Connections Instruction Manual 125 Outputs Sourcing example ...
Page 157: ...Controller Connections Instruction Manual 149 ...
Page 158: ...MODBUS TCP QB Expert Alpha Controller 150 ...
Page 175: ...Embedded PLC Instruction Manual 167 ...
Page 176: ......
Page 183: ...Multiple Spindle Instruction Manual 175 ...
Page 184: ... QB Expert Alpha Controller 176 ...
Page 201: ...Instruction Manual 193 Maintenance ...
Page 202: ...QB Expert Alpha Controller 194 ...
Page 203: ...10 QB Expert Alpha Controller Appendix A Torsion Compensation Angle Validation ...
Page 206: ......
Page 207: ...11 QB Expert Alpha Controller Glossary ...
Page 210: ......