Controller Connections
Instruction Manual
145
Outputs
Description
TASK SELECTED
Asserts when a task is selected by any means. Resets when the active task is complete.
Size: 1 bit
Configuration:
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Task: Type the task number that, when selected, asserts this output.
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
TASK SELECTED
BIT
Asserts when required to indicate the active task. This is one bit in a series of bits to create a binary number. As
tasks change so will the binary number created from these bits.
Size: 1 bit, except on fieldbus where it can be any size to fit the need.
Configuration:
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Bit: Type the number this bit will be in the binary number scheme for selected tasks.
Mode: All TASK SELECTED BITs must be the same mode, no mixing of modes allowed.
Binary – Creates a decimal number equivalent to the weighted value of this binary bit(s).
1 – Creates a number equivalent to the weighted value of this binary bit(s) and add the value
of one (1) to that number.
Spindle: Type the spindle number from which the signal come
s.
TOOL RUNNING
Asserts anytime the tool is energized. Resets when the tool is commanded to stop.
Size: 1 bit
Configuration:
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
*TORQUE
This output is the peak achieved torque value during the fastening cycle from the Audit step. It asserts when
the fastening cycle is complete (before the IN CYCLE bit resets). The value resets to zero (0) when the tool is
commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Step: Audit, Audit-1, Audit-2
Spindle: Type the spindle number from which the signal come
s.
TORQUE HIGH
Asserts at the end of a fastening cycle when the achieved torque value is above the High Torque limit for the
Audit step. Resets when the tool is commanded to start again. Can also be reset with the RESET RESULTS
STATUS input.
Size: 1 bit
Configuration:
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Step: Audit, Audit-1, Audut-2
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
Summary of Contents for QB Expert
Page 8: ......
Page 23: ...Introduction Instruction Manual 15 ...
Page 24: ......
Page 36: ......
Page 37: ...3 QB Expert Alpha Controller Programming SETUP Area SERVICE Area ANALYZE Area ...
Page 94: ......
Page 109: ...Instruction Manual 101 ...
Page 110: ......
Page 123: ...Instruction Manual 115 Tool Operation ...
Page 124: ......
Page 132: ...Input and Output Connector QB Expert Alpha Controller 124 Inputs example ...
Page 133: ...Controller Connections Instruction Manual 125 Outputs Sourcing example ...
Page 157: ...Controller Connections Instruction Manual 149 ...
Page 158: ...MODBUS TCP QB Expert Alpha Controller 150 ...
Page 175: ...Embedded PLC Instruction Manual 167 ...
Page 176: ......
Page 183: ...Multiple Spindle Instruction Manual 175 ...
Page 184: ... QB Expert Alpha Controller 176 ...
Page 201: ...Instruction Manual 193 Maintenance ...
Page 202: ...QB Expert Alpha Controller 194 ...
Page 203: ...10 QB Expert Alpha Controller Appendix A Torsion Compensation Angle Validation ...
Page 206: ......
Page 207: ...11 QB Expert Alpha Controller Glossary ...
Page 210: ......