Controller Connections
Instruction Manual
131
Inputs
Description
RESET JOB
When asserted, on any input, the controller resets the accumulated bolt count to zero for the active job and
acts as a part entry to re-enable the tool if disabled. The tool could be disabled due to “Error Proofing” and the
accumulated bolt count equal to target bolt count.
When removed nothing happens.
Size: 1 bit
Configuration:
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Spindle: Type the spindle number in which the job is to be reset.
RESET RESULT
STATUS
When asserted on any input bus, the controller resets to 0 (zero) any fastening cycle results status output bit on the
same bus. Meaning, if asserted on DeviceNet, only the DeviceNet output status bits are reset. Output status bits on
other buses will remain in their original state.
The list of status bits that will reset are:
CYCLE OK
CYCLE NOK
TORQUE OK
TORQUE HIGH
TORQUE LOW
ANGLE OK
ANGLE HIGH
ANGLE LOW
CYCLE ABORTED
CYCLE STOP
CURRENT OK
CURRENT HIGH
CURRENT LOW
When removed nothing happens.
Size: 1 bit
Configuration:
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Spindle: Type the spindle number in which the result status is to be reset.
REVERSE
When asserted on any input bus, the tool is placed in Reverse (disassembly) mode. This does NOT run the tool in
Reverse mode, it changes the tool mode from Forward to Reverse. If one input is required to do both functions, see
REVERSE START.
When removed, from any input type, the controller places the tool into Forward (assembly) mode.
Size: 1 bit
Configuration:
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Spindle: Type the spindle number for the tool to be put into reverse.
SELECT JOB
When asserted, on any input type, the controller makes this input’s Job the active Job.
When removed either nothing happens or if “Disable when open” is set to yes, then the tool becomes disabled.
Size: 1 bit
Configuration:
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Job: Type the job number to select when this input is asserted.
Disable when open:
Yes – Disables the tool when this input is removed.
No – Does not disable the tool upon input removal.
Spindle: Spindle: Type the spindle number in which the job is to be selected.
Summary of Contents for QB Expert
Page 8: ......
Page 23: ...Introduction Instruction Manual 15 ...
Page 24: ......
Page 36: ......
Page 37: ...3 QB Expert Alpha Controller Programming SETUP Area SERVICE Area ANALYZE Area ...
Page 94: ......
Page 109: ...Instruction Manual 101 ...
Page 110: ......
Page 123: ...Instruction Manual 115 Tool Operation ...
Page 124: ......
Page 132: ...Input and Output Connector QB Expert Alpha Controller 124 Inputs example ...
Page 133: ...Controller Connections Instruction Manual 125 Outputs Sourcing example ...
Page 157: ...Controller Connections Instruction Manual 149 ...
Page 158: ...MODBUS TCP QB Expert Alpha Controller 150 ...
Page 175: ...Embedded PLC Instruction Manual 167 ...
Page 176: ......
Page 183: ...Multiple Spindle Instruction Manual 175 ...
Page 184: ... QB Expert Alpha Controller 176 ...
Page 201: ...Instruction Manual 193 Maintenance ...
Page 202: ...QB Expert Alpha Controller 194 ...
Page 203: ...10 QB Expert Alpha Controller Appendix A Torsion Compensation Angle Validation ...
Page 206: ......
Page 207: ...11 QB Expert Alpha Controller Glossary ...
Page 210: ......