3-10
P
ROTEGÉ
® 616 I
NSTALLATION AND
M
AINTENANCE
M
ANUAL
, F
EBRUARY
2001
8) Plug the free end of the gray line cord into the
wall mounted modular jack.
3.4 Install Single-Line Phones and
Analog Devices
Follow the instructions provided with the single-line
phone or analog device for installation and connec-
tion. Singleline phones and analog devices must be
connected to analog adapters connected to the 6/6
KSU. Some analog devices, like voice mail systems,
may require additional software configuration. See
chapter 4, "Features," and chapter 5, "Programming,"
for more information.
4. Install Optional
Peripheral Equipment
Follow the instructions provided with optional
peripheral equipment. Such equipment may include
external paging systems and music on hold devices.
5. System Initialization
When the installation steps explained in this chapter
have been completed, the 616 system can be initial-
ized. Initialize by following these steps:
1) Ensure that the AC power cord is not con-
nected.
2) Turn the Ram Switch to the Reset position.
3) After 10 seconds, return the switch to the ON
position.
4) Connect the AC power cord.
5) Watch the red heartbeat LED for a flashing
heartbeat. It should begin after four to six
seconds. The Protegé® 616 system has now
completed initialization and the default data-
base is loaded. Turn to chapter 5, "Program-
ming," for more information about
customizing the database.
Important
The AC Adapter must be either plugged into or
unplugged from the AC outlet to apply or remove
power from the Protegé® 616 KSU.