Loop Distance and Cable Resistance Table 3-3 on
page 3-6. The table assumes the use of twisted pair 24
AWG wire.
1.4 Power Requirements
The KSU cabinet must be within 5 feet (1.5 meters) of
the isolated, dedicated, 105 - 125VAC, 57 - 63Hz, 15A,
single-phase commercial power receptacle. No other
equipment may be connected to the dedicated cir-
cuit.
A surge protector should be used to protect the
KSU from power surges and voltage spikes.
1.5 Environmental Conditions
As a general rule, if environmental conditions are
suitable for office personnel, they also are suitable for
Protegé equipment. The KSU may be safely operated
in temperatures ranging from 32° to 104° Fahrenheit
(0° to 40° Celsius), in relative humidity ranging from
5% to 95% (non-condensing), and at altitudes up to
10,000 feet. Ensure that these conditions will not be
exceeded under any circumstances (such as air con-
ditioning failure and tropical depressions). A prop-
erly controlled environment will extend equipment
life and help ensure reliable system operation.
1.6 Installation Safety Guidelines
(From UL 1459, a product safety specification for
telephone equipment.)
1) Never install telephone wiring during a light-
ning storm.
2) Never install telephone jacks in wet locations
unless the jack is designed for use in wet loca-
tions.
3) Never touch uninsulated telephone wires or
terminals unless the telephone line has been
disconnected at the network interface.
4) Use caution when installing or modifying tele-
phone lines.
1.7 Tools and Supplies
A basic list of tools and supplies required to install
the Protegé® 616 system is provided in the Tools and
Supplies Table. The list is intended for standard
telephony wiring practice. Sites requiring
EIA/TIA568A unshielded, twisted pair wiring stan-
dards require additional components.
1.8 Install MDF
The Main Distribution Frame (MDF) is where the
KSU, the station equipment and CO lines are
Requirements
Temperature - KSU
and Keysets
Relative Humidity
(non-condensing)
Altitude
In Operation
32° - 104° F
(0° - 40° C)
5% - 95%
10,000 feet
In Storage
-40° - 185° F
(-40° - 85° C)
5% - 95%
10,000 feet
Environmental Conditions
Table 3 - 1: Environmental Conditions
Qty
Description
1
Protegé® Business Display keyset for programming
1 pair
Side-cutter pliers
1 pair
Needle-nose pliers
1
Cable cutter
1 set
Common screwdrivers
1 set
Phillips-head screwdriver
1
Punch-down tool
1
Phone test set
1
High-impedance, Digital VOM, at least 0.5%
accuracy
1
Grounding wrist strap
1 pair
Safety glasses
1 pair
Gloves
1
66M1-50 type terminal blocks
Varies
Bridging clips
Varies
2 Twisted-pair 24 AWG cable
Varies
4-conductor modular jacks
Varies
Stranded #10 AWG or larger, copper ground wire
1
Amphenol interface connector
1
fl inch wooden backboard for MDF
Varies
Mounting hardware for backboard
Varies
Equipment for mounting MDF: drill, stud finder,
tape measure, etc.
Varies
Equipment for running station cables: cable puller,
drop-lights, drill, etc.
Tools and Supplies
Table 3 - 2: Tools and Supplies. This table provides a basic list of
tools and supplies for installing the 616 system with basic
telephony wiring practices.