28
CH1 FLOW RATE PID
Item
Description
Flow Rate PID OPEN LOOP
(on/off)
Toggles Duty Cycle PID on/off for specified channel
Flow Rate SP (GPM)
(read only)
Display desired flow rate setpoint.
Flow Rate PV
(read only)
Display of the current flow rate.
Flow Rate CF
(editable)
The flow rate correction factor is determined by running the PID in closed loop. It can be
manually adjusted while in open loop.
Kp
(editable)
Proportional value in the PID loop.
Ki
(editable)
Integral value in the PID loop.
Kd
(editable)
Derivative value in the PID loop.
Duty Cycle (%)
(read only)
Displays current duty cycle
PID DLY (mS)
(editable)
Sets the PID delay, or time until the PID begins working to allow for values to ramp up.
Graph Scale
(editable)
Change the scale of the graph for readability.
Liq Press PV (PSI)
(read only)
Displays current liquid pressure.