3.4 USER PASSWORDS AND MODBUS
USER PASSWORDS
MODBUS TAGS
3.5 RECOMMENDED MAINTENANCE
MONTHLY:
Check that all indicator lights work. Replace lamps as required.
Check all ribbon cable connections. Reinsert any partially inserted connectors.
Check all other cable type connections. Reinsert any partially inserted connectors.
EVERY 6 MONTHS:
Retighten all screw terminal connections to insure proper bonding.
Check all control relays to see that they are properly connected.
EVERY 12 MONTHS:
Check calibration of any controls that required calibration. Calibrate as required. See individual control component
manuals for calibration procedures.
Description
Username
Password
Operator
OPER
O
Engineer
ENG
E
PLC Tag Name
Variable
Type
Address
HMI_SPRAY_EN_CH1
BOOL
000001
ALARM_HORN
BOOL
000002
CH1_LEVEL_SENSOR_ALM
BOOL
000003
REM_CH1_RUN_INPUT
BOOL
000100
REM_CH2_RUN_INPUT
BOOL
000101
HMI_LIQ_PRESS_CH1
REAL
300001
-
300002
HMI_CH1_FM
REAL
300003
-
300004
CH1_LINE_SPEED
REAL
300005
-
300006
HMI_APP_RATE_CH1
REAL
300007
-
300008
DUTY_CYCLE_2008
REAL
300009
-
300010
FREQUENCY_2008
REAL
300017
-
300018
HMI_LIQ_PRESS_CH1
REAL
400001
-
400002
TOTAL_SPRAY_TM_2008
REAL
400011
-
400012
SYS_ON_TM_2008
REAL
400013
-
400014
GUN_CYCLES_2008
REAL
400015
-
400016
CH1_ACTIVE_RECIPE
INT
400100
CH2_ACTIVE_RECIPE
INT
400101