11
SECTION 5
RECIPE SETUP
5.1 RECIPE SCREEN OPERTIONS
Item
Description
Recipe #
(selection)
These arrows allow for the selection of the recipe displayed and available to be edited.
Please be aware this can change during operation.
Recipe Name
(editable)
Allows the user to associate a character string with each recipe number. This recipe name
will appear on the operating screen as the active recipe to assist the operator.
Timing Function
(selection)
Fixed Spray Time:
After seeing a trigger, will send spray signal for designated amount of
time.
Variable Spray Time:
Will send spray signal for the time the trigger is active.
Fixed Spray Distance:
After seeing a trigger, will send spray signal for designated amount of
distance.
Variable Spray Distance:
Will send spray signal for the distance the trigger is active.
Regulation
(selection)
Constant Flow, Air Act:
Uses I/P to regulate flow. Used with air actuated nozzles.
Constant Flow, PWM:
Based on the liquid pressure, reference flow and pressure, the con-
troller will calculate the correct duty cycle to maintain the flow rate setpoint. Used with
PWM nozzles only.
Application Rate, PWM:
This sets the system to apply a constant application rate of liquid
per unit of surface area of substrate on a moving conveyor. The flow rate of liquid will vary
as the line speed ramps up or down, but the add
-
on rate to the substrate will remain fixed.
Used with PWM nozzles only.
Freq & Duty Cycle, PWM:
This allows manual entry of frequency and duty cycle. Gun out-
put will not be determined by normal application logic. Used with PWM nozzles only.
Application Rate, Air Act:
This sets the system to apply a constant application rate of liquid
per unit of surface area of substrate on a moving conveyor. The flow rate of liquid will vary
as the line speed ramps up or down, but the add
-
on rate to the substrate will remain fixed.
Used with air actuated nozzles only.