36
9.4 CLEAN/PURGE SETTINGS
The Clean/Purge screen allows the user to configure and control clean/purge cycles.
9.5 2008 SETTINGS
2008 Settings screen is used to observe the settings in the 2008 module as decided by the active recipe. This screen
can also be used to change striping behavior priority at the extremes of the nozzle
’
s capabilities (Allow striping to
spray the correct quantity, disallow striping and spray to little, avoid striping by spraying at 100%).
Item
Description
Ch1 Purge
(editable)
Purges the fluid lines before an initial run of air ensuring nozzles are
full of fluid.
Ch1 Clean
(editable)
Pressing this button engages the clean process using the parameters
set for the given channel.
Clean Duty Cycle
(editable)
Enter the duty cycle the nozzles will use during the clean cycle.
Max Cycle Speed
(editable)
Enter the maximum cycle speed for the nozzles during the clean cycle.
Clean Time
(read only)
Enter the amount of time the nozzles will fire to clean the header.