FIXED SPRAY TIME
-
WITH REPEAT
This timing mode is used to create a continuous repetition of spray period for a fixed time.
Note:
See Configuration settings or Recipe Settings for more information on Timing Mode setup.
Repeat Spray: The system can generate a repeating pattern inside of a spray period.
Special Case: Repeat Spray, Air Overlap
: If repeat off
-
time <= (antic follower time), the air will remain on.
Note:
This can happen in both fixed and Variable spray times.
•
Sum of Anticipator and Follower Time is Higher Than Start Delay Time
—If (anticipator time + follower time) > off period, then the air will be kept on during the complete repeat cycle.
Repeat Spray
Repeat spray, air overlap
PARAMETER
VALUE
Start Delay
In seconds (s) or meters (m)
-
requires speed sensor
Off Period
In seconds (s) or meters (m), set value greater than 0
On Period
In seconds (s) or meters (m), set value greater than 0
Spray Period
In seconds (s) or meters (m), set value greater than 0
Anticipator Time
In seconds (s)
Follower Time
In seconds (s)