7.7 HEADER INFO
The header info screen is used to enter reference information about the header, enable or disable zone control, and
to determine which nozzles will be activated or deactivated in a particular zone configuration. The zone configuration
will be selected during the creation of recipes at the recipe setup screen. In the operation screen, the user can select
the recipe to run and the proper zone configuration will be used.
Item
Description
Analog INP 1
(read
-
only)
Displays the current analog input 1 reading
Span
(editable)
Set the 20 mA reading on the 4
-
20 mA scale for analog input 1
Analog INP 2
(read
-
only)
Displays the current analog input 2 reading
Span
(editable)
Set the 20 mA reading on the 4
-
20 mA scale for analog input 2
Ch1 Ethernet Rem SP
(read
-
only)
Displays the current channel 1 ethernet remote setpoint reading.
Ch2 Ethernet Rem SP
(read
-
only)
Displays the current channel 2 ethernet remote setpoint reading.
Remote Flow Rate (GPM)
(selection)
Select where the remote setpoint for Flow Rate is coming from
No Remote Input:
No remote input selected, system will use local setpoints
Analog Input:
Uses the analog input to determine the flow rate setpoint.
Ethernet:
Uses ethernet input to determine the flow rate setpoint
Remote AppRate (mL/SQ FT)
(selection)
Select where the remote setpoint for application rate is coming from
No Remote Input:
No remote input selected, system will use local setpoints
Analog Input:
Uses the analog input to determine the application rate setpoint.
Ethernet:
Uses ethernet input to determine the application rate setpoint
Item
Description
Spray Width
(editable)
Enter the total width of the spray pattern of the manifold.
Ref Flow
(editable)
Enter the reference flow of the manifold determined by the sum of the maximum capacity
of each nozzle/tip in the manifold.
Ref Pressure
(editable)
Enter the reference pressure at which the previous reference flow was determined.
Number of Zones
(editable)
Total number of zones in the selected zone configuration. (Maximum of 12 zones)
Zone Control
(toggle)
Enable or Disable zone control.
Zone Configuration
(selection)
Select the zone configuration to setup/modify.
Zone Setup
(toggle)
Allows user to enable or disable specific zones. The number of zones available corresponds
to the number entered under
“
Number of Zones
”