27
7.5 CH1 FLOW METER SETUP
Item
Description
Flow Meter 1
(editable)
Displays the channel 1 flow rate.
Flow Meter
(selection)
Selects the method of flow rate feedback for control loops.
Not Installed:
There is no flow meter installed. Certain features will not be enabled as they re-
quire liquid pressure feedback.
Installed:
There is a flow meter installed and will be used when utilizing relevant feedback
loops.
Manual:
Allows for a user to enter a flow rate that can be used for feedback loops instead of the actual
pressure.
Span
(editable)
Set the span of the atomizing air pressure sensor based on a 4
-
20mA scale, with 4mA being 0 by default
and 20mA will be the span you enter in this field.
Shot Volume
(selection)
Off:
Shot volume is off and hidden on the operating screen.
On:
Shot volume is on and displayed on the operating screen.
Shot Volume Alarm
on the alarms screen is
used to setup parameters.
Flow Inc
(editable)
Set the flow increment when using a flow meter with pulsed output for shot volume. Flow increment is
the volume per pulse of the flow meter output.
Ch1 Flow Rate PID
Takes the used to the channel 1 Flow Rate PID screen.
Ch1 App Rate PID
Takes the used to the channel 1 App Rate PID screen.