23
SECTION 7
CONFIGURATION SCREENS
ATTENTION
: Channel 1 and Channel 2 screens contain identical fields and options except where noted.
7.1 SYSTEM CONFIGURATION
Press the boxes to open a secondary screen
with editable fields for each feature.
7.2 CH1 LINE SPEED SETUP
System Configuration Screen
Item
Description
Line Speed 1
(editable)
Displays the channel 1 line speed
Line Speed
(selection)
Selects the method of line speed feedback for control loops.
Not Installed:
There is no encoder installed. Certain features will not be enabled as they re-
quire liquid pressure feedback.
Installed:
There is an encoder installed and will be used when utilizing relevant feedback
loops.
Manual:
Allows for a user to enter a line speed that can be used for feedback loops instead of the
actual line speed.
Copy From Ln Spd 1
(channel 2 only): Uses the line speed input from channel 1 for channel 2
Speed Signal Input
(selection)
Selects what kind of signal the encoder is sending.
HI SPD CTR 0:
For encoders sending a pulsed output.
Analog Input 1:
For encoders sending an analog output.
K
-
Factor (editable)
If an encoder is installed the encoder
’
s K
-
Factor can be entered here.
Span (editable)
In the case of an analog encoder the 20 mA signal is entered here.
Max Off Time
(editable)
Maximum time between encoder pulses before the system assumes a zero speed