8.3 ATOMIZING AIR PRESSURE ALARM SCREEN
8.4 FLOW ALARM SETUP
8.5 LIQUID LEVEL ALARM SETUP
Item
Description
Ch1 AAIR Press Alarm
(toggle)
Enables or disables the atomizing air pressure alarm.
Min Pressure
(editable)
Sets the minimum pressure allowable before alarming.
Max Pressure
(editable)
Sets the maximum pressure allowable before alarming.
Tolerance Time
(editable)
Sets the maximum allowable time outside the max or min pressure.
Item
Description
Ch1 Flow Alarm
(toggle)
Enables or disables the Flow alarm.
Low Percentage
(editable
Sets the minimum percentage of flow rate allowable before alarming. This percentage is
based off the setpoint in the active recipe.
High Percentage
(editable)
Sets the maximum percentage of flow rate allowable before alarming. This percentage is
based off the setpoint in the active recipe.
Tolerance Time
(editable)
Sets the maximum allowable time outside the max or min flow rate before alarming.
Item
Description
Ch1 Liq Level Alm
(toggle)
Enables or disables the liquid level alarm.
Tolerance Time
(editable)
Sets the maximum allowable time below the low level set on a level sensor before alarming.