Proprietary and Confidential
Error
Code
Error Description
Corrective Action
398
The requested feature is not
currently implemented
A requested feature of XDP is not
implemented. Recovery depends on what
operation was being attempted.
399
Missing argument
If you are using the XDP SDK and you
receive this error ensure that you are
passing all of the required parameters to
the procedure. It can also be an internal
error if the XDP SDK is not being used. In
that case contact XYPRO
400
Unable to access a
configuration file
Unable to access a configuration file. The
most likely cause is that the
file does not exist on the same subvolume
as the XDP library or it is corrupt.
401
unused
402
Version mismatch detected
between the XDP library and the
XDPCPU program
The XYGATEDP and the XDPCPU
programs came from different XDP
versions. Ensure that the
XDPCPU_PROCESSNAME_PREFIX is
correct in the DPCONF file.
403
Unable to open a configuration
file
Unable to open the DPCONF file. Ensure
that the
subvolume where the XDP library exists
and that it is secured so that the
application can access it.
404
Beginning encryption position is
before a key field and spans into
the key area
A field in the record is defined with a
po length that overlaps a record key
area but doesn't totally fill it. Redefine the
field's position or length.
405
A bad index was passed into the
context management
procedures
Internal error. Contact XYPRO.
406
Unable to share a memory
segment
Internal error. Contact XYPRO.
407
Memory allocation failure
Unable to allocate memory. Contact
XYPRO.
408
Unable to add data to the
encryption API (check the sub-
error code)
The encryption API rejected adding data.
Check the Audit file for additional
information.
409
Unable to get data from the
encryption API (check the sub-
error code)
The encryption API rejected getting data.
Check the Audit file for additional
information.
410
The required
=TCPIP^PROCESS^NAME
define is not present.
No =TCPIP^PROCESS^NAME define
exists and there is no $ztc0 process
running.