10-5 (P)
DSR-80/80P/60/60P
10-5-1. Recorder/Player Adjustment
10-5-1-1.
INT SC Frequency Adjustment
(Connection)
10-5-1-2.
HCK Adjustment
Conditions for adjustment
Adjustment
.....
Specification
.
STOP mode
.
REF. VIDEO IN ; No signal
TP601/IO-149 (B-2)
1
CT602/IO-149 (A-3)
Frequency counter
Spec. f=4,433,618
±
10 Hz
Conditions for adjustment
Adjustment
.....
Specification
.
STOP mode
Connection 1
TP602/IO-149 (A-4)
1
CT601/IO-149 (A-3)
Oscilloscope
Spec. A=2.50
±
0.05 Vdc