5-3
DSR-80/80P/60/60P
5-1-2. How to Reset Hours Meter
1. Set the switch S201-1 on the SY board to ON.
2. Press the
[MENU]
key.
3. Select HOURS METER using
[(]
,
[)]
keys.
4. Select the desired item to reset using
[(]
,
[)]
keys.
5. When the
[RESET]
key is pressed, the display changes to
“0000” which blinks.
6. When the
[SET]
key is pressed, a message appears requesting
approval to reset, on the monitor.
7. To reset the memory, press the
[SET]
key again to exit the
hours meter display mode.
Note :
The following message appears while saving data into
memory during reset.
If the main power is turned off while the message
appears, the memory will not be reset correctly. Do
not turn off the main power while the display appears.
8. Set the switch S201-1 on the SY board to OFF.