4-12
DSR-80/80P/60/60P
(2) TAPE TOP/END
Check the tape top and tape end sensors.
Pressing the
[SET]
(
[YES]
) key moves down the cassette
compartment and the display shown in the right appears.
1. Interrupt the tape top sensor by inserting finger or the like in
between the light emitter and receptor of the tape top sensor.
Confirm that the TOP SENSOR display changes from OFF to
ON on the monitor display.
2. Interrupt the tape top sensor by inserting finger or the like in
between the light emitter and receptor of the tape top sensor.
Confirm that the TOP SENSOR display changes from OFF to
ON on the monitor display.
In case of trouble :
If the display does not change from OFF to ON, check whether the
tape top sensor or the tape end sensor itself is defective.
Check also the tape top/tape end sensor circuit (PTC-85/86/87
board).
Tape top/end detect LED
Summary of Contents for DVCAM DSR-60
Page 2: ......
Page 54: ......
Page 174: ......
Page 220: ......
Page 236: ......
Page 238: ...8 2 N DSR 80 80P 60 60P SY 241B 241 CV101 CHARA SIZE 10 1 N DSR 60 80 ...
Page 242: ...8 2 P DSR 80 80P 60 60P SY 241B 241 CV101 CHARA SIZE 10 1 P DSR 60P 80P ...
Page 284: ......