6-4
DSR-80/80P/60/60P
5. Place the unit horizontally.
Note :
Be careful not to damage the tape guides
in the vicinity of the drum assembly, or
the tape running surfaces of the drum
assembly.
6. Remove the three screws (PS 2
x
6) securing the
drum assembly from the MD chassis, and
remove the drum assembly and dew sensor while
taking care not to let it touch the various guides.
Attachment
7. Clean the mounting surface of the new drum and
the mounting surface of the MD chassis using the
cleaning cloth moistened with cleaning fluid.
Note :
Be careful not to scratch the tape
running surface of the drum assembly or
the guides during cleaning.
8. Align the two positioning pins of the MD chassis
with the positioning holes in the bottom of the
drum assembly, then insert the drum assembly
into the MD chassis.
9. While pushing the drum assembly in the
direction of arrow (turning clockwise), fix the
drum assembly and dew sensor with the three
screws.
10. Connect the connectors and attach the
disassembled parts by reversing the removal
procedure from steps 6 to 1.
11. Clean the tape running surface of the drum
assembly using the cleaning cloth moistened
with cleaning fluid.
12. After cleaning, wipe the cleaned surface two or
three times with a dry cloth.
Adjustment After Replacement
13. Perform the Tape Path Adjustment.
(Refer to section 7-2.)
14. Perform the RF Adjustment.
(Refer to section 10-4.)
Dew sensor
Fixing screws
PS 2
x
6
Positioning hole
Mounting surface
Positioning pin
Tape guide
MD chassis
Positioning hole
Mounting surface
(rear)
Drum assembly
Summary of Contents for DVCAM DSR-60
Page 2: ......
Page 54: ......
Page 174: ......
Page 220: ......
Page 236: ......
Page 238: ...8 2 N DSR 80 80P 60 60P SY 241B 241 CV101 CHARA SIZE 10 1 N DSR 60 80 ...
Page 242: ...8 2 P DSR 80 80P 60 60P SY 241B 241 CV101 CHARA SIZE 10 1 P DSR 60P 80P ...
Page 284: ......